PM-1 power measuring board for LV & MV grids

PM-1

Measuring networks flexibly and efficiently

Module PM-1 allows cost-effective measurement of relevant network variables in low and medium voltage networks for monitoring the power supply and loads on the primary systems. It also allows for measurement of characteristic values for voltage quality in accordance with DIN EN 50160 and provides basic data as per ISO 50001.

The PM-1 is designed as an extension module which can be put into successful use after only a few configuration steps. All values are calculated directly in the module and do not load the core process. The network connection is by means of measurement transducers. Voltage measurement can be carried out directly in the LV network without needing expensive transformers.

Your individual contact person

Johann Kloucek
Johann Kloucek

Head of International Business Development
Tel.: +49 221 / 59 808158
E-Mail: johann.kloucek@sae-it.de

Show all contact persons

As an extension module from the net-line FW-5/FW-5-GATE series5+, the PM-1 is inserted into the I/O area of the bay station controller which also supplies it. setIT specifies the measurement parameters and the selection of measured values from V5.001. The values are integrated directly in the process data from where they can be monitored, sent and recorded based on custom criteria.

Application areas

  • Local network stations
  • Decentralised generation plants
  • Systems with decentralised voltage distribution
  • Industrial systems

Technische Daten

Easy integration

The PM-1 module is used as an extension to FW-5 series5+ and FW-5-GATE systems. It is inserted directly onto the TBUS of the station. Configuration is integrated fully in setIT. You can scale measurement variables here and perform a configuration phase by phase of the transformer ratios. Individual lower voltage limits can also be set. Overvoltage and overcurrent are set automatically.

The relevant measured values are freely selectable and are integrated directly in the process image of the station. Further evaluation can take place with the four-level limit monitoring of the measured values and the indication/logging functions of substation control.

 

46 Measurands

  • Voltages: U1, U2, U3, U12, U23, U31
  • Currents: I1, I2, I3, IN, Itotal
  • Active power: P1, P2, P3, Ptotal
  • Reactive power: Q1, Q2, Q3, Qtotal
  • Apparent power: S1, S2, S3, Stotal
  • Power: W1, W2, W3, Wtotal
  • Power facot: PF1, PF2, PF3, PFtottal
  • Energy: W1, W2, W3, Wtotal
  • Reactive energy: Wb1, Wb2, Wb3, Wbtotal
  • Frequency: f1, f2, f3, faverage
  • Total harmonic distortion I: THDI1, THDI2, THDI3
  • Total harmonic distortion U: THDU1, THDU2, THDU3
  • Temperature: T

Integrated totals

 

  • Energy: W1, W2, W3, Wtotal
  • Reactive energy: Wb1, Wb2, Wb3, Wbtotal

Indications

  • Load flow: L1, L2, L3
  • Overcurrent
  • Undervoltage
  • Rotary field disorder
  • faults
Kontakt

SAE IT-systems GmbH & Co. KG
Im Gewerbegebiet Pesch 14
50767 Cologne, Germany

Phone: +49 221 / 59 808-0
Fax: +49 221 / 59 808-60
E-Mail: info(at)sae-it.de

Hotline
Do you have technical problems?
Don't hesitate to contact us!

Phone: +49 221 / 59 808-55
E-Mail: service(at)sae-it.de

Contact Form

May we help you?
Do you have a question, like to get further information or just speak your mind?
*=mandatory

Repair application
If you want to report a faulty or damaged component, please use our repair application.

If you have questions, please contact our Repair and Service department: +49 221/59808-55

Top